IMPROVING THE CORRECTION ACCURACY OF FARADAY ROTATION BY USING TEC DATA RELEASED BY IGS
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Faraday rotation induced when electromagnetic wave penetrates through ionosphere is the major source for the cross polarization in observed Stokes brightness temperature with a polarimetric microwave radiometer. Faraday rotation correction employing TEC (total electron content) data generated by IRI (international reference ionosphere) model can not meet polarization rotation correction accuracy in some low latitude regions. To improve the correction accuracy, the following two methods were used: 1.integrating Faraday rotation angle along observation path and 2.correcting Faraday rotation by using TEC data released by IGS. Analysis results show that the first method is hardly helpful to improve the correction accuracy, while the second one can improve Faraday rotation correction accuracy considerably. By using TEC data, the correction method can satisfy the correction accuracy of polarization rotation angles which a polarimetric microwave radiometer demands.

    Reference
    Related
    Cited by
Get Citation

YAN Wei, SHI Jian-Kang, LU Wen. IMPROVING THE CORRECTION ACCURACY OF FARADAY ROTATION BY USING TEC DATA RELEASED BY IGS[J]. Journal of Infrared and Millimeter Waves,2010,29(3):225~229

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 06,2009
  • Revised:September 09,2009
  • Adopted:December 28,2009
  • Online: July 19,2010
  • Published:
Article QR Code