High-precision spot centroid positioning of high-frame-rate short-wave infrared images for satellite laser communication
CSTR:
Author:
Affiliation:

1.School of Physics and Optoelectronic Engineering, Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou 310024, China;2.Key Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China

Clc Number:

TN929.13

Fund Project:

Short-wave Infrared Camera Systems (B025F40622024)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The accuracy of spot centroid positioning has a significant impact on the tracking accuracy of the system and the stability of the laser link construction. In satellite laser communication systems, the use of short-wave infrared wavelengths as beacon light can reduce atmospheric absorption and signal attenuation. However, there are strong non-uniformity and blind pixels in the short-wave infrared image, which makes the image distorted and leads to the decrease of spot centroid positioning accuracy. Therefore, the high-precision localization of the spot centroid of the short-wave infrared images is of great research significance. A high-precision spot centroid positioning model for short-wave infrared is proposed to correct for non-uniformity and blind pixels in short-wave infrared images and quantify the localization errors caused by the two, further model-based localization error simulations are performed, and a novel spot centroid positioning payload for satellite laser communications has been designed using the latest 640×512 planar array InGaAs shortwave infrared detector. The experimental results show that the non-uniformity of the corrected image is reduced from 7% to 0.6%, the blind pixels rejection rate reaches 100%, the frame rate can be up to 2000 Hz, and the spot centroid localization accuracy is as high as 0.1 pixel point, which realizes high-precision spot centroid localization of high-frame-frequency short-wave infrared images.

    Reference
    Related
    Cited by
Get Citation

FU Peng, HE Dao-Gang, LIU Jun, WANG Yue-Ming. High-precision spot centroid positioning of high-frame-rate short-wave infrared images for satellite laser communication[J]. Journal of Infrared and Millimeter Waves,2025,44(1):59~70

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 04,2023
  • Revised:November 16,2024
  • Adopted:February 04,2024
  • Online: August 02,2024
  • Published:
Article QR Code