Passive millimeter wave focal plane array imaging technology
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Under the background of safety inspection, the key technologies of near-range passive millimeter wave focal plane array imaging are studied. The analysis of the system quasi-optics were carried out using fundamental Gaussian beam method combined with geometrical optics method. A multi-beam wide-angle scanning lens antenna was designed. A new dielectric rod antenna was devised, which is prone to be aligned in close arrays and provide good radiation to the lens. Miniaturized direct-detection radiometers were fabricated with high-sensitive in Ka-band . Experimental results of the 20-channel passive millimeter wave focal plane array imaging system are presented, which can be used to detect hidden objects on human bodies in near range indoors.

    Reference
    Related
    Cited by
Get Citation

WANG Nan-Nan, QIU Jing-Hui, ZHANG Peng-Yu, DENG Wei-Bo. Passive millimeter wave focal plane array imaging technology[J]. Journal of Infrared and Millimeter Waves,2011,30(5):419~424

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:July 04,2010
  • Revised:September 05,2010
  • Adopted:September 08,2010
  • Online: October 20,2011
  • Published:
Article QR Code