高光谱应用的带可调复位时间CDS的低噪声红外焦平面读出电路
作者:
作者单位:

1.中国科学院上海技术物理研究所 红外成像材料与器件重点实验室,上海 200083;2.中国科学院大学,北京 100049

作者简介:

通讯作者:

中图分类号:

O47

基金项目:


Low noise ROIC integrated with correlated double sampling with adjustable intervals for hyperspectral applications
Author:
Affiliation:

1.Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China;2.University of Chinese Academy of Sciences, Beijing 100049, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    低辐射量的高光谱应用对红外焦平面读出电路(ROIC)提出了低噪声的设计要求。相关双采样(CDS)是常用的减少噪声的结构。本文通过调节钳位和采样保持之间的时间间隔来改进CDS,可灵活消除低频噪声。采用180 nm CMOS工艺设计和制造了640×512规模、15 μm 像元中心距的读出电路。输入级集成了低噪声CTIA与本文提出的可调复位时间CDS(AICDS),所设计的时序产生器使CDS复位时间可以延长0~270个时钟周期。通过延长复位时间减少这个时间间隔,噪声电子数可以由39 e-减少到18.3 e-。SPECTRE仿真结果和实验测试结果证实了提出的AICDS结构可以提升高光谱应用读出电路的噪声性能,因此可以广泛应用。

    Abstract:

    Low noise is a key requirement of readout integrated circuit (ROIC) in hyperspectral applications for its low radiation. Correlated double sampling (CDS) is commonly used to suppress noise. In this paper, CDS is improved by adjusting the time interval between the clamp and sample-and-hold (SH), which can filter low-frequency noise flexibly. A 640×512, 15 μm pixel pitch ROIC is designed and fabricated in 180 nm CMOS process. The input stage consists of low-noise capacitive trans-impedance amplifier (CTIA) and CDS with adjustable intervals (AICDS). A timing generator is proposed to extend the CDS reset time from 0 to 270 clock cycles. By extending the reset time to decrease the time interval, the noise electrons are significantly decreased from 39 e- to 18.3 e-. The SPECTRE simulation and the experimental results corroborate that the proposed structure AICDS can optimize noise performance of hyperspectral ROIC, thus can be widely used.

    参考文献
    相似文献
    引证文献
引用本文

吴双,梁清华,陈洪雷,丁瑞军.高光谱应用的带可调复位时间CDS的低噪声红外焦平面读出电路[J].红外与毫米波学报,2024,43(2):269~276]. WU Shuang, LIANG Qing-Hua, CHEN Hong-Lei, DING Rui-Jun. Low noise ROIC integrated with correlated double sampling with adjustable intervals for hyperspectral applications[J]. J. Infrared Millim. Waves,2024,43(2):269~276.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2023-08-23
  • 最后修改日期:2024-02-22
  • 录用日期:2023-11-03
  • 在线发布日期: 2024-02-22
  • 出版日期:
文章二维码