p-on-n长波、甚长波碲镉汞红外焦平面器件技术研究
作者:
作者单位:

昆明物理研究所,昆明 650223

作者简介:

通讯作者:

中图分类号:

TN215

基金项目:

红外专项项目(LZX20190302)


Research on p-on-n LWIR and VLWIR HgCdTe infrared focal plane detectors technology
Author:
Affiliation:

Kunming Institute of Physics, Kunming 650223

Fund Project:

Infrared Special Project(LZX20190302)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    As注入掺杂的p-on-n结构器件具有暗电流小、R0A值高、少子寿命长等优点,是长波、甚长波碲镉汞红外焦平面器件发展的重要趋势。介绍了由昆明物理研究所研究制备的77 K温度下截止波长为9.5 μm、10.1 μm和71 K下14.97 μm 的p-on-n长波、甚长波碲镉汞红外焦平面器件,对器件的响应率、NETD、暗电流及R0A等性能参数进行测试分析。测试结果表明,器件的有效像元率在99.78%~99.9%之间,器件的NETD均小于21 mK。实现了p-on-n长波、甚长波碲镉汞红外焦平面器件的有效制备。

    Abstract:

    The p-on-n structure doped with As implantation has the advantages of low dark current,high R0A product, and long minority carrier lifetime,which is an important trend in the development of long-wavelength and very long-wavelength HgCdTe infrared focal plane detectors. P-on-n LWIR and VLWIR HgCdTe infrared focal plane detectors with cut-off wavelength of 9.5 μm and 10.1μm at 77 K and 14.97 μm at 71 K fabricated by Kunming Institute of Physics are introduced.Test and analyze performance parameters such as the responsivity, NETD, dark current and R0A of the detectors. The test results show that the operability of the detectors is between 99.78% and 99.9%,and the NETD of the detectors is less than 21 mK. The effective fabrication of p-on-n LWIR and VLWIR HgCdTe infrared focal plane detectors is realized.

    参考文献
    相似文献
    引证文献
引用本文

李立华,熊伯俊,杨超伟,李雄军,万志远,赵鹏,刘湘云. p-on-n长波、甚长波碲镉汞红外焦平面器件技术研究[J].红外与毫米波学报,2022,41(3):534~539]. LI Li-Hua, XIONG Bo-Jun, YANG Chao-Wei, LI Xiong-Jun, WAN Zhi-Yuan, ZHAO Peng, LIU Xiang-Yun. Research on p-on-n LWIR and VLWIR HgCdTe infrared focal plane detectors technology[J]. J. Infrared Millim. Waves,2022,41(3):534~539.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-09-06
  • 最后修改日期:2022-05-31
  • 录用日期:2021-10-09
  • 在线发布日期: 2022-05-27
  • 出版日期:
文章二维码