离子注入型硅掺砷阻挡杂质带长波红外探测器的研究
作者:
作者单位:

1.中国科学院上海技术物理研究所 红外物理国家重点实验室, 上海 200083;2.中国科学院大学北京 100049;3.上海师范大学 数理学院物理系上海 200234

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金和国家重点基础研究发展计划项目 11933006 61805060 61290304 10904158 10990103 2013CB632802 2011CB922004国家自然科学基金和国家重点基础研究发展计划项目(11933006, 61805060, 61290304,10904158, 10990103,2013CB632802,2011CB922004)


Ion-implanted Si:As blocked impurity band detectors for VLWIR detection
Author:
Affiliation:

1.State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China;2.University of Chinese Academy of Sciences, Beijing 100049, China;3.Department of Physics, College of Mathematics and Science, Shanghai Normal University, Shanghai 200234, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    研究了基于离子注入技术制备硅掺砷阻挡杂质带探测器的工艺,通过优化工艺条件和相关器件的结构与材料参数,制造了具有良好光电响应性能的长波红外探测器。在温度5 K,-3.8V工作偏压下,探测器的峰值响应波长为23.8μm,黑体响应率为3.7A/W,3.2V时最大探测率为5.2×1013 cm?Hz1/2/W。性能指标堪与文献报道的结果相媲美甚至更好,展示了离子注入工艺在制作阻挡杂质带探测器方面的潜在优势,特别是离子注入工艺与目前的微电子电路技术相兼容,能将探测器与读出电路集成到一块芯片上,在降低成本的同时提高探测器成像性能。

    Abstract:

    An ion-implant technique for fabricating Si:As blocked impurity band detectors for VLWIR detection had been investigated, and the detectors with good photoelectric response performance had been demonstrated by optimizing both the processing condition and the device structural parameters together with material characteristic parameters. At 5 K temperature, with a dc bias voltage of -3.8V, the peak response wavelength of the fabricated devices is 23.8 μm, the blackbody responsivity is 3.7A/W, and the detectivity is 5.3×1013cm?Hz1/2/W at 3.2V, which are comparable to (and even superior to) those reported in literatures. Especially, the device manufacturing process is compatible with that for fabrication of integrated circuit, and the detectors can be integrated with readout circuits on one chip, resulting in a remarkable reduction in produce cost and a significant improvement in the imaging performance.

    参考文献
    相似文献
    引证文献
引用本文

王超,李宁,戴宁,石旺舟,胡古今.离子注入型硅掺砷阻挡杂质带长波红外探测器的研究[J].红外与毫米波学报,2020,39(3):290~294]. WANG Chao, LI Ning, DAI Ning, SHI Wang-Zhou, HU Gu-Jin. Ion-implanted Si:As blocked impurity band detectors for VLWIR detection[J]. J. Infrared Millim. Waves,2020,39(3):290~294.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-10-05
  • 最后修改日期:2020-04-17
  • 录用日期:2019-11-08
  • 在线发布日期: 2020-04-15
  • 出版日期:
文章二维码