Variable-area hydrogenation of HgCdTe photovoltaic(PV) detectors was studied.It was found that the current-voltage(I-V) characteristic was obviously improved after hydrogenation,wherein dark current was gradually decreased as the hydrogenation area enlarged,and the zero-biased resistance was increased,meanwhile the current noise was reduced.By the comparison of experimental results and numerical fitting results,it was found that the improvement of I-V curves was related to hydrogenation zone.When the hydrogenation process was focused on the N-type zone,hydrogenation effect was mainly due to the reduction of minority carrier recombination centers caused by implantation process,which could increase the minority carrier lifetime.When the hydrogenation was enlarged to P-type zone,the improvement was primarily the result of the oppression of trap density in the surface depletion region,which led to the decrease of trap-assisted tunneling current.So it was concluded that the junctions of PV detectors formed by ion implantation were N P type.
参考文献
相似文献
引证文献
引用本文
乔辉,周文洪,叶振华,李向阳,龚海梅.碲镉汞光伏型探测器的变面积氢化研究[J].红外与毫米波学报,2008,27(6):]. QIAO Hui, ZHOU Wen-Hong, YE Zhen-Hua, LI Xiang-Yang, GONG Hai-Mei. STUDY ON VARIABLE-AREA HYDROGENATION OF HgCdTe PHOTOVOLTAIC DETECTORS[J]. J. Infrared Millim. Waves,2008,27(6).]