State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    To get actual response spectra of quantum type photodetectors from measured photo-current spectra using FTIR method, two feasible and convenient correction schemes of calculated instrument function scheme and standard detector transfer scheme are proposed. The feasibility, limitations and matters which need attention are discussed in detail. Based on those schemes, consistent response spectra of various shortwave infrared InGaAs photodetectors have been gained. A comparison has been made to the response spectrum measured using a precisely calibrated grating monochromator system and the validity of the schemes is confirmed.

    Abstract:

    To get actual response spectra of quantum type photodetectors from measured photo-current spectra using FTIR method, two feasible and convenient correction schemes of calculated instrument function scheme and standard detector transfer scheme are proposed. The feasibility, limitations and matters need attention are discussed in detail. Based on those schemes, consistent response spectra of various shortwave infrared InGaAs photodetectors have been gained. A comparison have been made to the response spectrum measured using a precisely calibrated grating monochromator system, the validity of the schemes is confirmed.

    参考文献
    相似文献
    引证文献
引用本文

张永刚,周立,顾溢,马英杰,陈星佑,邵秀梅,龚海梅,方家熊. FTIR测量的量子型光电探测器响应光谱校正[J].红外与毫米波学报,2015,34(6):737~743]. ZHANG Yong-Gang, ZHOU Li, GU Yi, MA Ying-Jie, CHEN Xing-You, SHAO Xiu-Mei, GONG Hai-Mei, FANG Jia-Xiong. Correction of response spectra of quantum type photodetectors measured by FTIR[J]. J. Infrared Millim. Waves,2015,34(6):737~743.]