Study of Properties of Passive Check Valve in MPCL
DOI:
CSTR:
Author:
Affiliation:

Shanghai Institute of Technical Physics of the Chinese Academy of Sciences,Shanghai,Shanghai Institute of Technical Physics of the Chinese Academy of Sciences,Shanghai,Shanghai Institute of Technical Physics of the Chinese Academy of Sciences,Shanghai

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A new passive check valve for Mechanical Pumped Cooling Loops (MPCL) is designed. Static structural analysis and flow characteristic simulation of the diaphragm-type passive check valve designed are performed by the software ANSYS. The forward flow and leak flow characteristics of the check valve are tested experimentally. The results show that the performance of the check valve can completely meet the requirements of the mechanical pump. The check valve is of referential significance to the research on the improvement of the performance of mechanical pumps.

    Reference
    Related
    Cited by
Get Citation

He Huixiang, Wu Yinong, Xie Rongjian. Study of Properties of Passive Check Valve in MPCL[J]. Infrared,2017,38(4):23~27

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Article QR Code