Analysis and verification of the positioning accuracy of a flat-panel detector used for precision pointing in space optical communication
CSTR:
Author:
Affiliation:

1.Key Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China;2.University of Chinese Academy of Sciences, Beijing 100049, China;3.School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China;4.Shanghai Quantum Science Research Center, Shanghai 201315, China

Clc Number:

TP

Fund Project:

Supported by the National Natural Science Foundation of China (U1738204), the Shanghai Rising-Star Program (19QA1410400), the Key Technologies Research and Development Program (2017YFA0303900), the Youth Innovation Promotion Association of the Chinese Academy of Sciences, the Shanghai Municipal Science and Technology Major Project (2019SHZDZX01).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To realize a high-precision link in space optical communication, we analyzed key factors that affect the accuracy of flat-panel detectors in terms of target positioning. The error of the centroid algorithm was analyzed from the mechanism and the necessity of satisfying the spatial lossless sampling condition was verified by using a simulation. The defined NU value served as an indicator in quantifying the nonuniformity of the detector. As the NU value increased linearly, the positioning error of the centroid continued to increase, whereas the speed reduced. When the NU value was 0.005, the maximum positioning error was 0.043 pixels. Considering that the light intensity of the target incident on the optical system varies constantly, the smaller the NU value, the closer the centroid is to the true position of the light spot. Furthermore, the pixel response of a typical complementary metal oxide semiconductor (CMOS) detector was experimentally tested under different illumination intensities. Based on the response curve, a mathematical model for the nonuniformity of the pixel response was established. It can be determined that the NU value fluctuates from 0.0045 to 0.0048 within the linear response range. The experimental results of the spot centroid positioning accuracy verify that the absolute positioning error is less than 0.05 pixels, which satisfies the requirements of high-precision links. Therefore, the effectiveness of the theory and simulation presented in this study can be validated.

    Reference
    Related
    Cited by
Get Citation

WANG Xu, TU Cheng-Xiang, ZHANG Liang, WANG Jian-Yu. Analysis and verification of the positioning accuracy of a flat-panel detector used for precision pointing in space optical communication[J]. Journal of Infrared and Millimeter Waves,2022,41(3):631~638

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 13,2021
  • Revised:May 20,2022
  • Adopted:October 09,2021
  • Online: May 20,2022
  • Published:
Article QR Code