STUDY ON TIME INTERVAL MEASUREMENT SYSTEM IN PHOTON COUNTING IMAGING LIDAR
DOI:
Author:
Affiliation:

Clc Number:

TN249

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The time intervals between laser main pulse and the corresponding multiple echoes were needed to measure in photon counting imaging lidar,and the system had to have high precision.The delay line interpolation method was used and a system with the resolution of 27ps was developed.The hardware and the software of the system were presented.The indexes such as the precision and linearity were tested.The results show that the precision can reach 80ps and the linearity is good.

    Reference
    Related
    Cited by
Get Citation

ZHU Lei, HUANG Geng-Hua, OUYANG Jun-Hua, SHU Rong, WANG Jian-Yu. STUDY ON TIME INTERVAL MEASUREMENT SYSTEM IN PHOTON COUNTING IMAGING LIDAR[J]. Journal of Infrared and Millimeter Waves,2008,27(6):

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online:
  • Published: