STUDIES OF DEEP DEFECT LEVELS IN Hg_(1-x)Cd_xTe
DOI:
Author:
Affiliation:

Clc Number:

TN213 O471.5

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The defect levels in Hg1-xCdxTe p+n junction photodiodes were studied by using Deep Levels Transient Spectroscopy (DLTS). Two electron traps, E(0.06), and E (0.15) and two hole traps, H (0.075) and H (0.29), were obtained, respectively. Their concentrations are only a few percent of shallow levels. According to these characteristic parameters, the minority lifetime of the devices and the product of area times the dynamic resistance at zero bias are estimated. The nature of some defect levels is suggested, too.

    Reference
    Related
    Cited by
Get Citation

Zhou Jie Feng Songlin Lu Liwu. STUDIES OF DEEP DEFECT LEVELS IN Hg_(1-x)Cd_xTe[J]. Journal of Infrared and Millimeter Waves,1994,13(5):359~363

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online:
  • Published: