Correction of response spectra of quantum type photodetectors measured by FTIR
Author:
Affiliation:

State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Key Laboratory of Infrared Imaging Materials and Devices,Shanghai Institute of Technical Physics,Chinese Academy of Sciences

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To get actual response spectra of quantum type photodetectors from measured photo-current spectra using FTIR method, two feasible and convenient correction schemes of calculated instrument function scheme and standard detector transfer scheme are proposed. The feasibility, limitations and matters need attention are discussed in detail. Based on those schemes, consistent response spectra of various shortwave infrared InGaAs photodetectors have been gained. A comparison have been made to the response spectrum measured using a precisely calibrated grating monochromator system, the validity of the schemes is confirmed.

    Reference
    Related
    Cited by
Get Citation

ZHANG Yong-Gang, ZHOU Li, GU Yi, MA Ying-Jie, CHEN Xing-You, SHAO Xiu-Mei, GONG Hai-Mei, FANG Jia-Xiong. Correction of response spectra of quantum type photodetectors measured by FTIR[J]. Journal of Infrared and Millimeter Waves,2015,34(6):737~743

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:November 24,2014
  • Revised:September 23,2015
  • Adopted:February 06,2015
  • Online: December 01,2015
  • Published: