77 K下碲镉汞APD探测器的高精度时间数字转换电路
作者:
作者单位:

1.中国科学院上海技术物理研究所 中国科学院红外成像材料与器件重点实验室,上海200083;2.中国科学院大学,北京 100049

作者简介:

通讯作者:

中图分类号:

TN29

基金项目:

国家自然科学基金青年基金(62104240)


High precision time-to-digital conversion circuit for mercury cadmium telluride APD detector at 77 K
Author:
Affiliation:

1.Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technology Physics, Chinese Academy of Sciences,Shanghai 200083, China;2.University of Chinese Academy of Sciences, Beijing 100049, China

Fund Project:

Supported by National Natural Science Foundation of China young Science Foundation(62104240)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    碲镉汞雪崩光电二极管(HgCdTe APD)是目前红外焦平面技术前沿研究之一,低温下高精度时间标记读出电路是APD焦平面的基础,直接影响到APD红外焦平面性能。时间数字转换电路(TDC)是实现高精度时间标记的方法之一。基于对低温下金属-氧化物半导体场效应晶体管(Metal-Oxide-Semiconductor Field-Effect Transistor, MOSFET)器件的分析,设计了一款游标型TDC电路,该方法利用同步计数器量化整数倍周期,实现粗计数6 bits的输出;通过片上锁相环倍频的高频时钟来量化不足一个时钟周期的部分,以实现精计数6 bits的输出。电路采用标准互补金属氧化物半导体(Complementary Metal Oxide Semiconductor, CMOS)工艺流片,工作在120 MHz的主频与77 K下测试得到,能够分辨最小精度为236.28 ps,其中微分非线性为-0.54~0.71 LSB,积分非线性为-1.32~1.21 LSB。

    Abstract:

    HgCdTe avalanche photodiode (APD) is the frontier research on infrared focal plane technology. High-precision time stamp''s readout circuit is the basis of the APD focal plane at 77 K, which directly affects APD infrared focal plane performance. Time-to-digital conversion circuit (TDC) is one of the methods to achieve high-precision time stamping. Based on the analysis of MOSFET device at low temperature, we design a vernier TDC circuit, which uses a synchronous counter to quantize an integer multiple of the periods to achieve a coarse count of 6 bits. We use the high-frequency clock multiplied by the on-chip phase-locked loop to quantify the part that is less than one clock cycle to achieve a fine-count of 6 bits output. The circuit adopts standard CMOS process tape out, and our circuit works at a master-frequency of 120 MHz. At 77 K, the circuit tests can distinguish the time resolution of 236.280 ps. The DNL is within -0.54~0.71 LSB, and the INL is within -1.32~1.21 LSB.

    参考文献
    相似文献
    引证文献
引用本文

章琪文,陈洪雷,丁瑞军.77 K下碲镉汞APD探测器的高精度时间数字转换电路[J].红外与毫米波学报,2022,41(1):362~369]. ZHANG Qi-Wen, CHEN Hong-Lei, DING Rui-Jun. High precision time-to-digital conversion circuit for mercury cadmium telluride APD detector at 77 K[J]. J. Infrared Millim. Waves,2022,41(1):362~369.]