高工作温度碲镉汞p-on-n中波1024×768焦平面探测器
作者:
作者单位:

昆明物理研究所,云南 昆明650223

作者简介:

通讯作者:

中图分类号:

TN215

基金项目:


High operating temperature p-on-n HgCdTe MWIR 1024×768 FPA detector
Author:
Affiliation:

Kunming Institute of Physics, Kunming 650223, China

Fund Project:

Supported by the National Key Research and Development Program of China (SQ2020YFB200190)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    提高红外探测器的工作温度对于减小红外系统的尺寸、重量和功耗至关重要,进而实现结构紧凑和成本低廉的红外系统。昆明物理研究所多年来对掺铟和砷离子注入技术的HgCdTe p-on-n技术进行了优化,实现了性能优异的中波红外探测器的研制。本文报道了高工作温度中波1024×768@10 μm红外焦平面阵列探测器的最新结果,并介绍了在150 K工作温度下的器件性能。结果标明,器件在150 K下截止波长为4.97 μm,并测得了不同工作温度下的NETD、暗电流和有效像元率。此外,还展示了在150 K的工作温度下焦平面器件的红外图像,并呈现了99.4%的有效像元率。

    Abstract:

    Increasing the operating temperature for infrared detectors is critical to reduce the size, weight and power of infrared (IR) systems. Such systems are essential to implement a compact and low-cost production of IR systems. For the Kunming Institute of Physics (KIP), HgCdTe standard p-on-n technology with indium doping and arsenic ion implantation technology has been optimized for many years and mid-wavelength IR (MWIR) detectors with excellent electro-optical performance were realized. This paper reports the latest results of the MWIR focal plane array (FPA) detector with a high operating temperature (HOT). Performances of the 1024×768@10 μm pitch MW detector working above 150 K were presented. The detector presenting a cut-off wavelength above 4.97 μm at 150 K has been developed. The noise-equivalent temperature difference (NETD), dark current and operability at different operating temperatures were attained. Additionally, the IR image taken with the MWIR HgCdTe-based FPA and processed at an operating temperature of 150 K was presented and retained an operability of 99.4%.

    参考文献
    相似文献
    引证文献
引用本文

何天应,秦强,孔金丞,覃钢,杨超伟,王向前,李红福,王琼芳,李永亮,杨翼虎,李轶民,宋林伟,杨秀华,罗云,陈楠,胡旭,赵俊,赵鹏.高工作温度碲镉汞p-on-n中波1024×768焦平面探测器[J].红外与毫米波学报,2023,42(6):711~715]. HE Tian-Ying, QIN Qiang, KONG Jin-Cheng, QIN Gang, YANG Chao-Wei, WANG Xiang-Qian, LI Hong-Fu, WANG Qiong-Fang, LI Yong-Liang, YANG Yi-Hu, LI Yi-Min, SONG Lin-Wei, YANG Xiu-Hua, LUO Yun, CHEN Nan, HU Xu, ZHAO Jun, ZHAO Peng. High operating temperature p-on-n HgCdTe MWIR 1024×768 FPA detector[J]. J. Infrared Millim. Waves,2023,42(6):711~715.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2023-03-31
  • 最后修改日期:2023-11-02
  • 录用日期:2023-04-18
  • 在线发布日期: 2023-11-01
  • 出版日期:
文章二维码