基于光通量倍增法的傅里叶红外探测系统光谱响应度非线性测量
作者:
作者单位:

1.长春理工大学 理学院,吉林 长春 130022;2.中国计量科学研究院 热工计量科学研究所,北京 100029

作者简介:

通讯作者:

中图分类号:

TN216

基金项目:

国家自然科学基金 11772318国家自然科学基金(11772318)


Nonlinearity measurements of spectral responsivity of Fourier transform infrared spectrometer measurement system based on flux superposition principle
Author:
Affiliation:

1.School of Science, Changchun University of Science and Technology, Changchun 130022, China;2.Div. of Thermophysics and Process Measurements, National Institute of Metrology, Beijing 100029, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    在宽动态范围、高分辨力、宽频谱红外辐射测量中,傅里叶变换红外光谱仪(FTIR)是常用的探测单元,其光谱响应度的非线性是宽动态范围红外光谱测量的不确定度主要贡献项之一。基于光通量倍增原理,建立傅里叶红外光谱探测系统的非线性测量实验系统。实验研究了在非线性测量典型时间段内的黑体辐射源和FTIR红外光谱探测系统的漂移特性,设计了测量序列变换模型来消除测量过程中的一阶线性漂移影响。在200~1 000℃范围内,实验测量了FTIR红外光谱探测系统的非线性特征,给出了在典型波长3.9 μm和10.6 μm处的非线性测量结果及相应的不确定度。

    Abstract:

    In infrared radiation temperature measurements of wide-dynamic, high-resolution and wide-spectrum, Fourier Transform infrared (FTIR) spectrometer is a commonly used measurement unit. The nonlinearity of the spectral responsivity is one of the main uncertainty contributions to wide dynamic infrared spectrum measurements of radiation sources. Based on the flux superposition principle, nonlinearity measurement system of FTIR spectrometer measurement system was established. The experimental research on the drift characteristics of the blackbody radiation source and FTIR spectrometer measurement system during the representative nonlinearity measurement time were carried out. The quasi-linear drift effects on the nonlinearity measurement were eliminated by permuting the aperture measurement order. The nonlinear characteristics of FTIR spectrometer measurement system were experimentally measured at 200~1 000℃. The nonlinearity measurement results and associated uncertainties at 3.9 μm and 10.6 μm are reported respectively.

    参考文献
    相似文献
    引证文献
引用本文

宋旭尧,端木庆铎,董伟,原遵东,李志彬,卢小丰,曲岩.基于光通量倍增法的傅里叶红外探测系统光谱响应度非线性测量[J].红外与毫米波学报,2020,39(4):409~416]. SONG Xu-Yao, DUANMU Qing-Duo, DONG Wei, YUAN Zun-Dong, LI Zhi-Bin, LU Xiao-Feng, QU Yan. Nonlinearity measurements of spectral responsivity of Fourier transform infrared spectrometer measurement system based on flux superposition principle[J]. J. Infrared Millim. Waves,2020,39(4):409~416.]

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2019-10-17
  • 最后修改日期:2020-07-27
  • 录用日期:2019-12-16
  • 在线发布日期: 2020-07-23
  • 出版日期:
文章二维码