    摘要:

    讨论了红外成像技术检测金属管内壁腐蚀时管壁外表面所覆盖的低导热系数(LTC)层所产生的噪声.从理论和实验上研究了LTC层对不同加载方式所产生的不同影响,还从理论上提出了一种处理严重LTC层影响的新方法.

    Abstract:

    The noise produced by a randomly distributed low thermal conductivity (LTC) layer on the outer surface of a metal tube when using infrared imaging technique to detect the corrosion defects on the inner surface of the tube was studied. The different influences of LTC layer on different heat loading methods were also studied both theoretically and experimentally. A new approach to diminish the high power noise produced by LTC layer was proposed in the end.

    参考文献
    相似文献
    引证文献
引用本文

杨黎俊 卢元军.低导热系数物质在红外成像检测中的影响及其处理[J].红外与毫米波学报,1997,16(6):431~436]. YANG Li Jun GENG Wan-Zhen JIANG Lin Zhen ZOU Li Xun WEI Gong Ming HONG Jin. INFLUENCE AND TREATMENT OF LOW THERMAL CONDUCTIVITY SUBSTANCE IN INFRARED IMAGING TESTING[J]. J. Infrared Millim. Waves,1997,16(6):431~436.]